<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>CIP Improvement Archives - Milktronics Online instruments</title>
	<atom:link href="https://www.milktronics.com/product-category/applications/cip-improvement/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.milktronics.com/product-category/applications/cip-improvement/</link>
	<description>Optimize Your Process</description>
	<lastBuildDate>Fri, 05 Nov 2021 16:59:02 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://www.milktronics.com/wp-content/uploads/2017/07/cropped-ski-milk-production-2-32x32.jpg</url>
	<title>CIP Improvement Archives - Milktronics Online instruments</title>
	<link>https://www.milktronics.com/product-category/applications/cip-improvement/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Online turbidity meter Aseptic processes High temperature process</title>
		<link>https://www.milktronics.com/product/0-300000ntu-turbidity-meter-remote-electronics-high-temperature-turbidity-remote-electronics-water-product-changeover/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Thu, 10 Aug 2017 15:43:28 +0000</pubDate>
				<guid isPermaLink="false">http://milktronics.com.cp25.ezhostingserver.com/?post_type=product&#038;p=2717</guid>

					<description><![CDATA[<p>Perfect sensor for phase transition in dairies. Designed for wet environment and high temperature processes during SIP or CIP.</p>
<p>Turbidity range 0-300000NTU, Milk, cream, skim, whey, juice, beer, fruit, white mass.</p>
<p>The post <a href="https://www.milktronics.com/product/0-300000ntu-turbidity-meter-remote-electronics-high-temperature-turbidity-remote-electronics-water-product-changeover/">Online turbidity meter Aseptic processes High temperature process</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Online robust turbidity sensor for aseptic processes.</p>
<ul>
<li>High temperature turbidity, remote electronics, water product changeover</li>
<li>CIP, HTST improvements, silo to silo, separator, FAT monitoring, Moisture control</li>
<li>Deviation: 0,1%,</li>
<li>300F process continious, 360F for 20 minutes</li>
<li>Probe seal : kalrez as a standard</li>
<li>Sapphire lens</li>
<li>Process fitting: Tri-clamp 1.5", 2",2.5",3" or flange or welded coupling</li>
<li>Cable : 33ft PVC</li>
<li>Extended history is available via a USB port.</li>
<li>HART available</li>
<li>Power 24VDC, Output (1) 4-20mA (turbidity), Output (2) 4-20mA (temperature)</li>
</ul>
<p style="text-align: left;">Easy to install, the meter will read 50 times / seconds the product consistency. When the change happens (water to product to water) the detection is done instantly. The meter has a 4-20mA output easily calibrated and connects to any automation or PLC. Plug and play sensor , robust and affordable for any budgets...</p>
<p>Manufacturer : <a href="http://www.satron.com/tmp_satron_site_0.asp?sua=2&amp;lang=3&amp;s=7">Satron INC Tampere</a></p>
<p>Recommended ordering code : VOM HJ223NRT417TB</p>
<p>The post <a href="https://www.milktronics.com/product/0-300000ntu-turbidity-meter-remote-electronics-high-temperature-turbidity-remote-electronics-water-product-changeover/">Online turbidity meter Aseptic processes High temperature process</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CIP improvement meter</title>
		<link>https://www.milktronics.com/product/cip-improvement-meter/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 28 Jul 2017 12:05:35 +0000</pubDate>
				<guid isPermaLink="false">http://milktronics.com.cp25.ezhostingserver.com/?post_type=product&#038;p=2650</guid>

					<description><![CDATA[<div><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">VOM Code NJ 221 N0T 007</span></span></div>
<div>Tri clamp size to be specified: 1,5" or 2" other size available, including aseptic flanges.</div>
<div>High temperature (300F) option available for aseptic or UHT processes.</div>
<div><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">ROI: 4 weeks</span></span></div>
<p>The post <a href="https://www.milktronics.com/product/cip-improvement-meter/">CIP improvement meter</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>The turbidity meter is placed on the CIP return line. During the first rinse the turbidity goes down once the lines are cleared. As the tubidity is low then the wash can be stopped. ROI=4 weeks</div>
<div>Savings are made on:</div>
<div>-Water</div>
<div>-energy</div>
<div>-acid/chemical</div>
<div>-turnover time</div>
<p>The post <a href="https://www.milktronics.com/product/cip-improvement-meter/">CIP improvement meter</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Phase transition</title>
		<link>https://www.milktronics.com/product/online-turbidity-meter/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 28 Jul 2017 11:44:46 +0000</pubDate>
				<guid isPermaLink="false">http://milktronics.com.cp25.ezhostingserver.com/?post_type=product&#038;p=2640</guid>

					<description><![CDATA[<p>Perfect for raw whey, Milk, Cream, dairy products, Juice, beer etc..</p>
<p>The post <a href="https://www.milktronics.com/product/online-turbidity-meter/">Phase transition</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Designed for CIP/SIP. Perfect for all industries.</p>
<ul>
<li>Power: 24VDC</li>
<li>Range 0-25000 NTU</li>
<li>Deviation 0.1%</li>
<li>LED long life</li>
<li>No drift possible, no recalibration.</li>
<li>All process fittings available</li>
<li>Aseptic option available</li>
<li>Process temperature : 212 F</li>
<li>Process temperature: 300 F (with high temperature option)</li>
<li>HART protocol</li>
<li>Output (1) 4-20mA Turbidity</li>
<li>Output (2) 4-20mA Temperature</li>
<li>Seals choice: EPDM, Viton, Kalrez</li>
<li>PVC cable up to 200 feet</li>
<li>Wetted parts choice : Aisi316L (standard), HAST, Titanium, Duplex</li>
<li>Automatic cleaning available</li>
</ul>
<p>The post <a href="https://www.milktronics.com/product/online-turbidity-meter/">Phase transition</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
