<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>COW Water 5NTU Archives - Milktronics Online instruments</title>
	<atom:link href="https://www.milktronics.com/product-category/applications/cow-water-5ntu/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.milktronics.com/product-category/applications/cow-water-5ntu/</link>
	<description>Optimize Your Process</description>
	<lastBuildDate>Tue, 17 Oct 2023 17:30:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://www.milktronics.com/wp-content/uploads/2017/07/cropped-ski-milk-production-2-32x32.jpg</url>
	<title>COW Water 5NTU Archives - Milktronics Online instruments</title>
	<link>https://www.milktronics.com/product-category/applications/cow-water-5ntu/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Condensate Of Whey turbidity meter COW</title>
		<link>https://www.milktronics.com/product/condensate-whey-meter/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 28 Jul 2017 12:21:20 +0000</pubDate>
				<guid isPermaLink="false">http://milktronics.com.cp25.ezhostingserver.com/?post_type=product&#038;p=2654</guid>

					<description><![CDATA[<p>Perfectly adapted meter for this application 0-20NTU.</p>
<p>Remote display available. Comes with tri-clamps and Tuchenhagen Varivant access unit pipe.</p>
<p>The post <a href="https://www.milktronics.com/product/condensate-whey-meter/">Condensate Of Whey turbidity meter COW</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Very accurate instrument to measure suspended particles (turbidity) in the COW water.</p>
<p>Typical calibration is 0-20NTU and the divert happens at 5NTU.</p>
<p>The instrument comes precalibrated with usually 3 points of calibration. 0NTU, 10NTU and 40NTU. this calibration can be customized by the user.</p>
<p>Features of the instrument:</p>
<p>-HART compatible</p>
<p>-UL, 3A, EHEDG , CE, FDA certificates available</p>
<p>-Power: 24VDC</p>
<p>-output: 4-20mA</p>
<p>-LED Wavelength : 460nm Blue (the meter will detect turbidity and non turbid particles)</p>
<p>-Local display, remote display available</p>
<p>-Tuchenhagen Varivant Spool piece 2", 2.5", 3", 4", and 6" available with tri-clamp or threads or flanges</p>
<p>&nbsp;</p>
<p>The post <a href="https://www.milktronics.com/product/condensate-whey-meter/">Condensate Of Whey turbidity meter COW</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VOD 0-1500NTU Turbidity Absorption remote display</title>
		<link>https://www.milktronics.com/product/vod-0-1500ntu-uv-nir-absorption-remote-display/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Wed, 12 Jul 2017 15:29:10 +0000</pubDate>
				<guid isPermaLink="false">http://milktronics.com.cp25.ezhostingserver.com/?post_type=product&#038;p=2577</guid>

					<description><![CDATA[<p>Very accurate on low turbidity levels. 0-5NTU applications such as COW, polisher or reverse osmosis. Robust, easy to install, the meter comes plug and play. Many display options.</p>
<p>The post <a href="https://www.milktronics.com/product/vod-0-1500ntu-uv-nir-absorption-remote-display/">VOD 0-1500NTU Turbidity Absorption remote display</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Very sensitive meter to detect impurities in water. Perfect for polisher, Reverse osmosis or COW water. Calibration is usually 0-20NTU. When the contamination reaches 5NTU the flow is diverted to waste. Perfectly hygienic, the meter comes the pipe and is already calibrated on Formazin. High temperature option is available for condensate applications.</p>
<ul>
<li>Absorption Range : 0-10-50-1500 FTU-NTU-g/L-%...(any range available)</li>
<li>High temperature option available 300°F  150°C</li>
<li>100°C (212°F)  150°C (300°F) continuous with high temperature option</li>
<li>LED long life aging auto-compensated</li>
<li>180° light transmission.</li>
<li>Power: 24VDC Output : 4-20mA</li>
<li>HART protocole</li>
<li>seals: EPDM, Viton, Kalrez</li>
<li>1" to 6" pipe diameter available</li>
<li>Wavelengths infrared (880nm NIR)</li>
<li>auto cleaning available</li>
<li>UL, 3A, EHEDG, CA, FDA certificates available</li>
</ul>
<p><img decoding="async" class="alignnone size-medium wp-image-7167" src="https://www.milktronics.com/wp-content/uploads/2017/07/certificates-Satron-1-300x105.jpg" alt="Turbidity meter with UL 3A EHEDG CE" width="300" height="105" srcset="https://www.milktronics.com/wp-content/uploads/2017/07/certificates-Satron-1-300x105.jpg 300w, https://www.milktronics.com/wp-content/uploads/2017/07/certificates-Satron-1-370x130.jpg 370w, https://www.milktronics.com/wp-content/uploads/2017/07/certificates-Satron-1.jpg 753w" sizes="(max-width: 300px) 100vw, 300px" /></p>
<p>The post <a href="https://www.milktronics.com/product/vod-0-1500ntu-uv-nir-absorption-remote-display/">VOD 0-1500NTU Turbidity Absorption remote display</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
