<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Online sensors Archives - Milktronics Online instruments</title>
	<atom:link href="https://www.milktronics.com/product-category/online-rosemount-sensors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.milktronics.com/product-category/online-rosemount-sensors/</link>
	<description>Optimize Your Process</description>
	<lastBuildDate>Fri, 28 Mar 2025 22:37:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://www.milktronics.com/wp-content/uploads/2017/07/cropped-ski-milk-production-2-32x32.jpg</url>
	<title>Online sensors Archives - Milktronics Online instruments</title>
	<link>https://www.milktronics.com/product-category/online-rosemount-sensors/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Residual Chlorine Cl2 analyzer</title>
		<link>https://www.milktronics.com/product/residual-chlorine-cl2-analyzer/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 28 Mar 2025 22:14:31 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=10935</guid>

					<description><![CDATA[<p>Model  TEM-CL803</p>
<p>The post <a href="https://www.milktronics.com/product/residual-chlorine-cl2-analyzer/">Residual Chlorine Cl2 analyzer</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Model  TEM-CL803 Residual chlorine analyzer</p>
<p><strong>-  3.5-inch color LCD screen for a simple and user-friendly interface</strong></p>
<p><strong>-  Measures residual chlorine, chlorine dioxide, and ozone</strong></p>
<p><strong>-  Easily switch between residual chlorine mode and ozone mode via the menu</strong></p>
<p><strong>-  Enables control of drug dosing</strong></p>
<p><strong>-  Supports 4-20mA and RS485 communication protocols</strong></p>
<p><strong>-  Offers multiple calibration methods</strong></p>
<p><strong>-  Includes temperature compensation for accurate readings</strong></p>
<p><strong>-  Protective back cover for enhanced durability and anti-interference</strong></p>
<p><strong>-  Optional data saving and export functions for easy data management</strong></p>
<p><strong>-  Constant voltage electrode with a simple structure, allowing for easy cleaning and replacement</strong></p>
<p><strong>-  Built-in storage chip saves up to one year of historical data and supports data export via mobile Bluetooth (optional)</strong></p>
<table class="table" style="height: 700px;" border="1" width="461" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td class="xl64">Measurement range</td>
<td class="xl65">0~20.00mg/L,</p>
<p>resolution 0.01mg/L;</td>
</tr>
<tr>
<td class="xl64">Residual chlorine measurement accuracy</td>
<td class="xl65">±0.02pH;</td>
</tr>
<tr>
<td class="xl64">Temperature measurement range</td>
<td class="xl65">0~99.9℃ (maximum -9.9~135℃); Graduation value: 0.1℃</td>
</tr>
<tr>
<td class="xl64">Temperature measurement accuracy</td>
<td class="xl65">±0.5℃;</td>
</tr>
<tr>
<td class="xl66">Automatic temperature<br />
compensation range</td>
<td class="xl65">0~99.9℃,25℃ as the reference;</td>
</tr>
<tr>
<td class="xl64">Sample flow rate</td>
<td class="xl65">200 to 250 mL/min</td>
</tr>
<tr>
<td class="xl64">Minimum detection limit</td>
<td class="xl65">0.01mg/L;</td>
</tr>
<tr>
<td class="xl64">Current isolation output</td>
<td class="xl65">4~20mA</td>
</tr>
<tr>
<td class="xl64">Output current error</td>
<td class="xl65">≤1%FS</td>
</tr>
<tr>
<td class="xl64">Input Power</td>
<td class="xl65">24VAC/220V/110v, 3A</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.milktronics.com/product/residual-chlorine-cl2-analyzer/">Residual Chlorine Cl2 analyzer</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Maselli UR24</title>
		<link>https://www.milktronics.com/product/online-refractometer-sugar-brix/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Thu, 25 Jun 2020 13:01:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=6044</guid>

					<description><![CDATA[<p>Online UR24 Refractometer for BRIX measurement 3A certified</p>
<p>The post <a href="https://www.milktronics.com/product/online-refractometer-sugar-brix/">Maselli UR24</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Application: Measurement of liquid products in process lines in Food, Chemicals, Textiles, Petrochemical<br />
industries, etc. in continuous or batch plants.<br />
Measurement type: Continuous refractometric measurement of Refraction Index and display in “BRIX” or “USER” scale of relative concentration, with automatic temperature compensation</p>
<p>The UR24 digital refractometer is a stand-alone unit designed for simple installation in-line or in a tank or vessel. It continuously measures concentration and displays and outputs the result in Brix or nD or % concentration with high accuracy. It also features a user programmable scale for specific applications.</p>
<p>Exists with 3A certificates for food industries</p>
<table id="tablepress-25" class="tablepress tablepress-id-25" style="height: 1021px;" width="738">
<tbody class="row-hover">
<tr class="row-2 even">
<td class="column-1"><strong>Measurements limits:</strong></td>
<td class="column-2"><strong>Prism in Sapphire:</strong> 1.3170...1.5318 nD (0...95 Brix)<br />
<strong>Prism in Sapphire LR:</strong> 1.3170…1.4030 nD (0…40 Brix)</td>
</tr>
<tr class="row-3 odd">
<td class="column-1"><strong>Accuracy:</strong></td>
<td class="column-2">With reference to standard sucrose solutions:<br />
<strong>Standard Accuracy version:</strong><br />
0.5% of Scale Range; maximum accuracy ±0.0002 nD (±0.15 Brix).<br />
<strong>High Accuracy version (HA):</strong><br />
0.3% of Scale Range; maximum accuracy ±0.00007 nD (±0.05 Brix)<br />
<strong>Super Accuracy version (SA):</strong><br />
0.1% of Scale Range; accuracy ±0.00003 nD (±0.02 Brix) valid for maximum product and/or ambient temperature variations of ±10 °C (±18 °F)</td>
</tr>
<tr class="row-4 even">
<td class="column-1"><strong>Measurement scales:</strong></td>
<td class="column-2">“BRIX” or “USER”; the “BRIX” scale refers to the nD/Bx ICUMSA (1974) conversion tables; the “USER” scale can be configured at the time of the order</td>
</tr>
<tr class="row-5 odd">
<td class="column-1"><strong>Response time:</strong></td>
<td class="column-2">1.8 seconds</td>
</tr>
<tr class="row-6 even">
<td class="column-1"><strong>Product temperature during measuring:</strong></td>
<td class="column-2">-5 °C...+105 °C with automatic compensation of temperature measured by Pt100. Special version for temperatures up to 140 °C</td>
</tr>
<tr class="row-7 odd">
<td class="column-1"><strong>Maximum temperature during sanitization:</strong></td>
<td class="column-2">125 °C (257 °F) x 30 min or 145 °C (293 °F) x 30 min for the “LP” version</td>
</tr>
<tr class="row-8 even">
<td class="column-1"><strong>Response time to variations in temperature:</strong></td>
<td class="column-2">2’/10 °C (18 °F).</td>
</tr>
<tr class="row-9 odd">
<td class="column-1"><strong>Relative Line Pressure:<br />
</strong></td>
<td class="column-2">max. 10 bar (145 psi) at 20 °C (68 °F)<br />
max. 8 bar (116 psi) at 100 °C (212 °F)<br />
Special configuration for pressures till 25 bar (362 psi) at 100 °C (212 °F)</td>
</tr>
</tbody>
</table>
<p><img decoding="async" class="alignnone size-full wp-image-7206" src="https://www.milktronics.com/wp-content/uploads/2020/06/3-a_logo_certificate.gif" alt="3A logo Refractometer" width="100" height="85" /></p>
<p>For the waste water version please click here : https://www.milktronics.com/product/ur-62-maselli/</p>
<p>The post <a href="https://www.milktronics.com/product/online-refractometer-sugar-brix/">Maselli UR24</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Metrohm 7010 TOC</title>
		<link>https://www.milktronics.com/product/metrohm-toc/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Tue, 21 May 2019 19:16:44 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=5191</guid>

					<description><![CDATA[<h2>Reliable online TOC measurements</h2>
<div class="g-row">
<div class="g-cell s-2of3 h-content-split">
<div class="mod mod-richtext">
<div class="r-content">
<h2><span style="color: #ffffff;"><strong>The 7010 TOC Analyser is designed for simple and reliable operation</strong></span></h2>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.milktronics.com/product/metrohm-toc/">Metrohm 7010 TOC</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>Reliable online TOC measurements</h1>
<div class="g-row">
<div class="g-cell s-2of3 h-content-split">
<div class="mod mod-richtext">
<div class="r-content">
<p><strong>The 7010 TOC Analyser is designed for simple and reliable operation.</strong></p>
<p>It uses the UV persulfate oxidation method with carbon dioxide detection by non dispersive infrared analysis. This analyser requires minimum maintenance due to a cleverly designed liquids compartment which uses larger diameter tubing and no valves, virtually eliminating the risk of blockages.</p>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.milktronics.com/product/metrohm-toc/">Metrohm 7010 TOC</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Rosemount 326P Pressure transmitter</title>
		<link>https://www.milktronics.com/product/rosemount-326p/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Tue, 14 May 2019 17:06:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=5094</guid>

					<description><![CDATA[<p>Rosemount™ 326P Pressure Transmitter The Rosemount 326P Pressure Transmitter is specifically engineered for pressure and hydrostatic level applications in the food and beverage industry. A variety of industry standard process connections, hygienic certifications (3-A, FDA, EC 1935, etc.), a polished stainless steel housing, and the ability to withstand clean-in-place processes enable the transmitter to meet your process requirements while minimizing&#160;<a href="https://www.milktronics.com/product/rosemount-326p/" class="read-more">Continue Reading</a></p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-326p/">Rosemount 326P Pressure transmitter</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="top namePartPriceContainer">
<div id="PageHeading_3074457345619346760">
<h1 class="main_header" role="heading" aria-level="1">Rosemount<img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 326P Pressure Transmitter</h1>
</div>
<div class="clear_float"><span style="font-size: 16px;">The Rosemount 326P Pressure Transmitter is specifically engineered for pressure and hydrostatic level applications in the food and beverage industry. A variety of industry standard process connections, hygienic certifications (3-A, FDA, EC 1935, etc.), a polished stainless steel housing, and the ability to withstand clean-in-place processes enable the transmitter to meet your process requirements while minimizing contamination risks and assuring product safety.</span></div>
<div>
<div class="col-xs-12 col-sm-4 col-md-3">
<div class="row">
<div class="col-xs-12 col-sm-4 col-md-3">
<h3>Specifications</h3>
</div>
<div id="specButton-6700021" class="col-xs-12 col-sm-8 col-md-9"></div>
</div>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Accuracy</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">0.20%</dd>
</dl>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Communication Protocol</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">4-20mA, Switch</dd>
</dl>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Rangedown</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">4:1</dd>
</dl>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Measurement Range</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">Up to 360 psig (24,8 bar)</dd>
</dl>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Process Temperature</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">Up to 257°F (125°C); 293°F (145°C) for a maximum of 1 hour</dd>
</dl>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Process Wetted Material</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">Ceramic, PTFE, 316L SST Polished to Ra &lt; 16 µ-in. (0.4 µ-m)</dd>
</dl>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Diagnostics</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">Basic diagnostics</dd>
</dl>
<dl class="row generic-attr">
<dt class="col-xs-12 col-sm-4 col-md-3">Certifications/Approvals</dt>
<dd class="col-xs-12 col-sm-8 col-md-9">3-A, FDA, EC 1935, EC 2023, see product data sheet for complete list of certifications</dd>
</dl>
<h3>Features</h3>
</div>
<div class="col-xs-12 col-sm-7 col-md-5">
<ul>
<li>G1" process connection is compatible with full suite of hygienic process connection adapters</li>
<li>Compact form factor enables installation in applications with space constraints</li>
<li>M12 electrical connector allows for simple installation and start-up</li>
<li>Local Operator Interface (LOI) for simple, local commissioning on-site without the use of extra tools</li>
<li>Configurable switch output for indication of abnormal pressure conditions</li>
<li>Designed to withstand CIP processes as well as external</li>
</ul>
</div>
</div>
</div>
<p>The post <a href="https://www.milktronics.com/product/rosemount-326p/">Rosemount 326P Pressure transmitter</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Retractable Rosemount 228 conductivity probe</title>
		<link>https://www.milktronics.com/product/retractable-rosemount-228-conductivity-probe/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Sat, 24 Feb 2018 01:04:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=3870</guid>

					<description><![CDATA[<p>The Model 226 and 228 toroidal (inductive) conductivity sensors consist of a pair of wire-wound metal toroids overmolded with either corrosion resistant PEEK or Tefzel®1. When the sensor is immersed in a conductive liquid and an AC voltage is applied to the drive coil, a voltage is induced in the liquid surrounding the coil. The voltage causes an ionic current&#160;<a href="https://www.milktronics.com/product/retractable-rosemount-228-conductivity-probe/" class="read-more">Continue Reading</a></p>
<p>The post <a href="https://www.milktronics.com/product/retractable-rosemount-228-conductivity-probe/">Retractable Rosemount 228 conductivity probe</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Model 226 and 228 toroidal (inductive) conductivity sensors consist of a pair of wire-wound metal toroids overmolded with either corrosion resistant PEEK or Tefzel®1. When the sensor is immersed in a conductive liquid and an AC voltage is applied to the drive coil, a voltage is induced in the liquid surrounding the coil. The voltage causes an ionic current to flow proportional to the conductance of the liquid. The ionic current induces a current in the receive coil, which the analyzer measures. The<br />
induced current is directly proportional to the conductivity of the solution.<br />
Toroidal sensors work well in highly conductive liquids, up to about<br />
2 S/cm (2,000,000 uS/cm). Performance in low conductivity samples<br />
is somewhat limited, with the minimum conductivity depending on the<br />
dimensions of the toroids, the number of windings in each, and the<br />
analyzer. When used with the Model 1056 and 56 analyzer the limits<br />
are 15 uS/cm for the 228 sensor and 5 uS/cm for the 226 sensor. When<br />
used with other instruments, the limits are 200 uS/cm for the 228 sensor, and 50 uS/cm for the 226 sensor.<br />
The measurement is insensitive to flow rate and direction. The sensor must be installed so that it is completely flooded, and the toroid hole must remain open.<br />
The Model 226 and 228 sensors have integral RTDs to allow temperaturecompensated<br />
conductivity measurements.<br />
A insertion/retraction assembly is available for the Model 228</p>
<p>The post <a href="https://www.milktronics.com/product/retractable-rosemount-228-conductivity-probe/">Retractable Rosemount 228 conductivity probe</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Toroidal 228 Rosemount conductivity probe 228-02-20-54-61</title>
		<link>https://www.milktronics.com/product/toroidal-228-rosemount-conductivity-probe/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Sat, 24 Feb 2018 00:52:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=3866</guid>

					<description><![CDATA[<p>Rosemount conductivity probe model 228  suitable with transmitter model 56 or 1056</p>
<p>The post <a href="https://www.milktronics.com/product/toroidal-228-rosemount-conductivity-probe/">Toroidal 228 Rosemount conductivity probe 228-02-20-54-61</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Rosemount conductivity probe model 228  suitable with transmitter model 56 or 1056</p>
<p>The Model 226 and 228 toroidal (inductive) conductivity sensors consist of a pair of wire-wound metal toroids overmolded with either corrosion resistant PEEK or Tefzel®1. When the sensor is immersed in a conductive liquid and an AC voltage is applied to the drive coil, a voltage is induced in the liquid surrounding the coil. The voltage causes an ionic current to flow proportional to the conductance of the liquid. The ionic current induces a current in the receive coil, which the analyzer measures. The<br />
induced current is directly proportional to the conductivity of the solution.</p>
<p>The post <a href="https://www.milktronics.com/product/toroidal-228-rosemount-conductivity-probe/">Toroidal 228 Rosemount conductivity probe 228-02-20-54-61</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Toroidal Rosemount 226 conductivity probe</title>
		<link>https://www.milktronics.com/product/rosemount-226/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Sat, 24 Feb 2018 00:48:10 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=3861</guid>

					<description><![CDATA[<p>Rosemount Analytical toroidal conductivity sensors are ideal for use in corrosive liquids or in liquids containing high levels of suspended solids that would otherwise corrode or foul metal-electrode sensors. Toroidal conductivity sensors are also well-suited for measuring highly conductive electrolyte solutions. Toroidal sensors work well in highly conductive liquids, up to about 2 S/cm (2,000,000 uS/cm). Performance in low conductivity&#160;<a href="https://www.milktronics.com/product/rosemount-226/" class="read-more">Continue Reading</a></p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-226/">Toroidal Rosemount 226 conductivity probe</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Rosemount Analytical toroidal conductivity sensors are ideal for use in corrosive liquids or in liquids containing high levels of suspended solids that would otherwise corrode or foul metal-electrode sensors. Toroidal conductivity sensors are also well-suited for measuring highly conductive electrolyte solutions.</p>
<p>Toroidal sensors work well in highly conductive liquids, up to about 2 S/cm (2,000,000 uS/cm). Performance in low conductivity samples is somewhat limited, with the minimum conductivity depending on the dimensions of the toroids, the number of windings in each, and the analyzer. When used with the Model 1056 and 56 analyzer the limits are 15 uS/cm for the 228 sensor and 5 uS/cm for the 226 sensor. When used with other instruments, the limits are 200 uS/cm for the 228 sensor, and 50 uS/cm for the 226 sensor.</p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-226/">Toroidal Rosemount 226 conductivity probe</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Rosemount Toroidal 225</title>
		<link>https://www.milktronics.com/product/rosemount-conductivity-probe-2/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 16 Feb 2018 17:08:25 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=3824</guid>

					<description><![CDATA[<p>Toroidal 225 Rosemount conductivity probe. Perfect for CIP in food and beverage industries.</p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-conductivity-probe-2/">Rosemount Toroidal 225</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Meet Various Sanitary Requirements<br />
-USP Class VI compliant<br />
-FDA food contact 21CFR177.2415 compliant<br />
-3-A Sanitary Standard 74-06 compliant<br />
Ease of Installation<br />
- 2 inch tri-clamp process connection<br />
- Installation flexibility with maximum cable lengths up to 200 ft (61 m) between sensor and transmitter when paired with remote junction box (sold separately)</p>
<p>High performance and Reliability<br />
- Robust measurements - insensitive to process flow and direction<br />
- Meet application compatibility requirements with a selection of chemical resistant body options including PEEK and Tefze</p>
<p>Code: 225-03-56</p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-conductivity-probe-2/">Rosemount Toroidal 225</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Rosemount model 1056</title>
		<link>https://www.milktronics.com/product/rosemount-conductivity-probe/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 16 Feb 2018 17:08:11 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=3823</guid>

					<description><![CDATA[<p>Independent Dual Input Measurements  Expandable to two channels of liquid analytical measurements: pH/ORP, Conductivity, Free Chlorine, Total Chlorine, Dissolved Oxygen, Ozone, and Turbidity.  Modular boards with auto-recognition of sensor board.  Large, easy to read, user customizable display of dual measurements in addition to diagnostic and temperature readings. Reduced Installation and Maintenance Time  Shorter installation times using&#160;<a href="https://www.milktronics.com/product/rosemount-conductivity-probe/" class="read-more">Continue Reading</a></p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-conductivity-probe/">Rosemount model 1056</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Independent Dual Input Measurements<br />
 Expandable to two channels of liquid analytical<br />
measurements: pH/ORP, Conductivity, Free Chlorine, Total<br />
Chlorine, Dissolved Oxygen, Ozone, and Turbidity.<br />
 Modular boards with auto-recognition of sensor board.<br />
 Large, easy to read, user customizable display of dual<br />
measurements in addition to diagnostic and temperature<br />
readings.<br />
Reduced Installation and Maintenance Time<br />
 Shorter installation times using Quick Start programming at<br />
initial install or after factory reset.<br />
 Effortlessly connect with PLCs and DCS' by choosing the HART<br />
or Profibus DP communication options.<br />
 Display measurements, configure alarms, and conduct<br />
maintenance with a simple to use local operator interface.<br />
 Efficiently manage your devices using intuitive device<br />
dashboards on AMS/475 Communicators.<br />
Accurate, Linear and Reliable Measurements of<br />
Analytical Sensors<br />
 Faster calibration of pH sensors using auto pH Buffer solution<br />
detection.<br />
 Linear conductivity measurements with on-board<br />
concentration curves for common acids and bases.<br />
 Built-in features to easily display accurate amperometric and<br />
turbidity measurements.</p>
<p>Code 1056-01-20-38-AN</p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-conductivity-probe/">Rosemount model 1056</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Transmitter Rosemount model 56-02-20-38-HT</title>
		<link>https://www.milktronics.com/product/rosemount-56-dual-input-transmitter/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 16 Feb 2018 16:49:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=3819</guid>

					<description><![CDATA[<p>Independent Dual Input Measurements  Expandable to two channels of liquid analytical measurements: pH/ORP, Conductivity, Free Chlorine, Total Chlorine, Dissolved Oxygen, Ozone, and Turbidity.  Modular boards with auto-recognition of sensor board.  Large, easy to read, user customizable screen that displays two measurements in addition to diagnostic and temperature readings. Reduced Installation and Maintenance Time  Do more using&#160;<a href="https://www.milktronics.com/product/rosemount-56-dual-input-transmitter/" class="read-more">Continue Reading</a></p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-56-dual-input-transmitter/">Transmitter Rosemount model 56-02-20-38-HT</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Independent Dual Input Measurements<br />
 Expandable to two channels of liquid analytical<br />
measurements: pH/ORP, Conductivity, Free Chlorine, Total<br />
Chlorine, Dissolved Oxygen, Ozone, and Turbidity.<br />
 Modular boards with auto-recognition of sensor board.<br />
 Large, easy to read, user customizable screen that displays<br />
two measurements in addition to diagnostic and temperature<br />
readings.<br />
Reduced Installation and Maintenance Time<br />
 Do more using a powerful device with data logging capability<br />
and PID control.<br />
 Shorter installation times using Quick Start programming at<br />
initial install or after factory reset.<br />
 Effortlessly connect with PLCs and DCS' by choosing the HART<br />
or Profibus DP communication options and manage devices<br />
using AMS/475 Communicators.<br />
 Display measurements, configure alarms, and conduct<br />
maintenance with a graphical local operator interface.<br />
Accurate, Linear, and Reliable Measurements of<br />
Analytical Sensors<br />
 Faster calibration of pH sensors using auto pH Buffer solution<br />
detection.<br />
 Linear conductivity measurements with on-board<br />
concentration curves for common acids and bases<br />
 Built-in features to easily display accurate amperometric and<br />
turbidity measurements.</p>
<p>Code : 56-02-20-38-HT</p>
<p>The post <a href="https://www.milktronics.com/product/rosemount-56-dual-input-transmitter/">Transmitter Rosemount model 56-02-20-38-HT</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
