<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Brix Archives - Milktronics Online instruments</title>
	<atom:link href="https://www.milktronics.com/product-tag/brix/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.milktronics.com/product-tag/brix/</link>
	<description>Optimize Your Process</description>
	<lastBuildDate>Thu, 27 Apr 2023 23:21:15 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://www.milktronics.com/wp-content/uploads/2017/07/cropped-ski-milk-production-2-32x32.jpg</url>
	<title>Brix Archives - Milktronics Online instruments</title>
	<link>https://www.milktronics.com/product-tag/brix/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Micropolar LB 5650 Total solids</title>
		<link>https://www.milktronics.com/product/micropolar-lb-5650/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 25 Sep 2020 15:39:13 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=6384</guid>

					<description><![CDATA[<p>Concentration  Dry Substance-Brix-content Measured by Micro-waves</p>
<p>The post <a href="https://www.milktronics.com/product/micropolar-lb-5650/">Micropolar LB 5650 Total solids</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Microwave meter to be installed on tanks or on large pipe.</p>
<p>Measurement principle: microwave</p>
<p>Antennas material: peek</p>
<p>Sensor body : stainless steel</p>
<p>Applications:</p>
<p>-Total solids</p>
<p>-Brix in sugar plants</p>
<p>-Wastewater (primary clarifier pumping, thickening process, Digester, Sludge dewatering, Dry cake optimization)</p>
<p>The post <a href="https://www.milktronics.com/product/micropolar-lb-5650/">Micropolar LB 5650 Total solids</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>UR-62 Maselli Refractometer</title>
		<link>https://www.milktronics.com/product/ur-62-maselli/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Fri, 26 Jun 2020 13:37:18 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=6079</guid>

					<description><![CDATA[<p>Online refractometer for BRIX measurement in drains or sewers, for all industries.</p>
<p>The display is optional. The meter can send a direct signal to the plant HMI.</p>
<p>The post <a href="https://www.milktronics.com/product/ur-62-maselli/">UR-62 Maselli Refractometer</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The UR62 digital refractometer is a probe designed for <strong>simple installation</strong> in-line or in a tank or vessel. It continuously measures concentration and displays and outputs the result in Brix or nD or % concentration with <strong>basic accuracy</strong>. The UR62 will signal to the process when concentration is outside of specifications or has reached its target end point by means of analogue 4-20 <strong>mA output</strong>. The probe is easily set up and configured through a PC or portable computing device using its built in RS485 interface. It can also be connected to the <strong>optional RC-24</strong> touch screen operator display unit. The analyzer does not have <strong>any drift</strong> in the time so that it does not need any adjustment vs the laboratory: after the initial configuration during start up, the operators in the plant do not have to touch the system anymore. Due to the optical technology, the equipment is virtually <strong>no maintenance</strong>: the robust construction with 316 stainless steel and IP67 protection, allows the installation in any aggressive environment using various Maselli mounting adapters.</p>
<div id="tab-tech" class="etabs-content active">
<table id="tablepress-72" class="tablepress tablepress-id-72">
<tbody class="row-hover">
<tr class="row-1 odd">
<td class="column-1"><strong>Application:</strong></td>
<td class="column-2">Measurement of liquid products in process lines in Food, Chemicals, Textiles, Petrochemical industries, etc. in continuous or batch plants</td>
</tr>
<tr class="row-2 even">
<td class="column-1"><strong>Measurement limits:</strong></td>
<td class="column-2">1.3170…1.4907 nD (0…80 Brix)</td>
</tr>
<tr class="row-3 odd">
<td class="column-1"><strong>Accuracy:</strong></td>
<td class="column-2">With reference to standard sucrose solutions.<br />
0.6% of the range; maximum accuracy ±0.0004 nD (±0.20 Brix) with minimum range.</td>
</tr>
<tr class="row-4 even">
<td class="column-1"></td>
<td class="column-2"></td>
</tr>
<tr class="row-5 odd">
<td class="column-1"><strong>Resolution:</strong></td>
<td class="column-2">0.2 Brix or equivalent</td>
</tr>
<tr class="row-6 even">
<td class="column-1"><strong>Product temperature during measuring:</strong></td>
<td class="column-2">5...+90 °C (23...194 °F).<br />
with automatic compensation for temperature measured by internal Pt1000 Temperature Probe, Class "A" (IEC-751). The maximum value depends on the type of installation (totally or partially immersed, conditioning system if installed, etc.) For product temperatures over 70°C (158°F) maximum immersion of the instrument must be 30 mm.<br />
Version with integrated prism cleaning system, the maximum temperature is 50 °C (122 °F).</td>
</tr>
<tr class="row-7 odd">
<td class="column-1"><strong>Maximum temperature during sanitization:</strong></td>
<td class="column-2">Hot water at 95 °C (203 °F) for 30’ / steam (0.5 bar) at 110 °C (230 °F) for 30’</td>
</tr>
<tr class="row-8 even">
<td class="column-1"><strong>Input/output</strong></td>
<td class="column-2">24V DC/ 4-20mA/ RS485</td>
</tr>
<tr class="row-9 odd">
<td class="column-1"><strong>Relative line pressure:</strong></td>
<td class="column-2">max. 10 bar (145 psi) at 20 °C (68 °F)<br />
max. 8 bar (116 psi) at 90 °C (194 °F)</td>
</tr>
</tbody>
</table>
</div>
<p>Installation examples:</p>
<p>In a effluent stream:              In a bassin or tank:          In a CIP hub drain:</p>
<p><img decoding="async" class="alignnone wp-image-9519" src="https://www.milktronics.com/wp-content/uploads/2020/06/drain-ur62-webpage-picture-300x248.jpg" alt="Refractoemter brix drain" width="186" height="154" srcset="https://www.milktronics.com/wp-content/uploads/2020/06/drain-ur62-webpage-picture-300x248.jpg 300w, https://www.milktronics.com/wp-content/uploads/2020/06/drain-ur62-webpage-picture-370x306.jpg 370w, https://www.milktronics.com/wp-content/uploads/2020/06/drain-ur62-webpage-picture.jpg 703w" sizes="(max-width: 186px) 100vw, 186px" />       <img decoding="async" class="alignnone wp-image-9520" src="https://www.milktronics.com/wp-content/uploads/2020/06/ur62-bassin-201x300.jpg" alt="brix refrac meter for drain sugar" width="128" height="191" srcset="https://www.milktronics.com/wp-content/uploads/2020/06/ur62-bassin-201x300.jpg 201w, https://www.milktronics.com/wp-content/uploads/2020/06/ur62-bassin-370x551.jpg 370w, https://www.milktronics.com/wp-content/uploads/2020/06/ur62-bassin.jpg 634w" sizes="(max-width: 128px) 100vw, 128px" />        <img decoding="async" class="alignnone wp-image-9521" src="https://www.milktronics.com/wp-content/uploads/2020/06/refract-pro-300x212.jpg" alt="refractometer brix cip hub drain" width="265" height="187" srcset="https://www.milktronics.com/wp-content/uploads/2020/06/refract-pro-300x212.jpg 300w, https://www.milktronics.com/wp-content/uploads/2020/06/refract-pro-1024x722.jpg 1024w, https://www.milktronics.com/wp-content/uploads/2020/06/refract-pro-768x542.jpg 768w, https://www.milktronics.com/wp-content/uploads/2020/06/refract-pro-370x261.jpg 370w, https://www.milktronics.com/wp-content/uploads/2020/06/refract-pro.jpg 1370w" sizes="(max-width: 265px) 100vw, 265px" /></p>
<p>On a pipe:</p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-9525" src="https://www.milktronics.com/wp-content/uploads/2020/06/on-a-pipe-UR62-installation-1-300x143.jpg" alt="Refractometer with 2&quot; tri-clamp on pipe before EQ tank" width="300" height="143" srcset="https://www.milktronics.com/wp-content/uploads/2020/06/on-a-pipe-UR62-installation-1-300x143.jpg 300w, https://www.milktronics.com/wp-content/uploads/2020/06/on-a-pipe-UR62-installation-1-768x366.jpg 768w, https://www.milktronics.com/wp-content/uploads/2020/06/on-a-pipe-UR62-installation-1-370x176.jpg 370w, https://www.milktronics.com/wp-content/uploads/2020/06/on-a-pipe-UR62-installation-1.jpg 993w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p>The post <a href="https://www.milktronics.com/product/ur-62-maselli/">UR-62 Maselli Refractometer</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Maselli UR24</title>
		<link>https://www.milktronics.com/product/online-refractometer-sugar-brix/</link>
		
		<dc:creator><![CDATA[Sylvain Dehec]]></dc:creator>
		<pubDate>Thu, 25 Jun 2020 13:01:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.milktronics.com/?post_type=product&#038;p=6044</guid>

					<description><![CDATA[<p>Online UR24 Refractometer for BRIX measurement 3A certified</p>
<p>The post <a href="https://www.milktronics.com/product/online-refractometer-sugar-brix/">Maselli UR24</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Application: Measurement of liquid products in process lines in Food, Chemicals, Textiles, Petrochemical<br />
industries, etc. in continuous or batch plants.<br />
Measurement type: Continuous refractometric measurement of Refraction Index and display in “BRIX” or “USER” scale of relative concentration, with automatic temperature compensation</p>
<p>The UR24 digital refractometer is a stand-alone unit designed for simple installation in-line or in a tank or vessel. It continuously measures concentration and displays and outputs the result in Brix or nD or % concentration with high accuracy. It also features a user programmable scale for specific applications.</p>
<p>Exists with 3A certificates for food industries</p>
<table id="tablepress-25" class="tablepress tablepress-id-25" style="height: 1021px;" width="738">
<tbody class="row-hover">
<tr class="row-2 even">
<td class="column-1"><strong>Measurements limits:</strong></td>
<td class="column-2"><strong>Prism in Sapphire:</strong> 1.3170...1.5318 nD (0...95 Brix)<br />
<strong>Prism in Sapphire LR:</strong> 1.3170…1.4030 nD (0…40 Brix)</td>
</tr>
<tr class="row-3 odd">
<td class="column-1"><strong>Accuracy:</strong></td>
<td class="column-2">With reference to standard sucrose solutions:<br />
<strong>Standard Accuracy version:</strong><br />
0.5% of Scale Range; maximum accuracy ±0.0002 nD (±0.15 Brix).<br />
<strong>High Accuracy version (HA):</strong><br />
0.3% of Scale Range; maximum accuracy ±0.00007 nD (±0.05 Brix)<br />
<strong>Super Accuracy version (SA):</strong><br />
0.1% of Scale Range; accuracy ±0.00003 nD (±0.02 Brix) valid for maximum product and/or ambient temperature variations of ±10 °C (±18 °F)</td>
</tr>
<tr class="row-4 even">
<td class="column-1"><strong>Measurement scales:</strong></td>
<td class="column-2">“BRIX” or “USER”; the “BRIX” scale refers to the nD/Bx ICUMSA (1974) conversion tables; the “USER” scale can be configured at the time of the order</td>
</tr>
<tr class="row-5 odd">
<td class="column-1"><strong>Response time:</strong></td>
<td class="column-2">1.8 seconds</td>
</tr>
<tr class="row-6 even">
<td class="column-1"><strong>Product temperature during measuring:</strong></td>
<td class="column-2">-5 °C...+105 °C with automatic compensation of temperature measured by Pt100. Special version for temperatures up to 140 °C</td>
</tr>
<tr class="row-7 odd">
<td class="column-1"><strong>Maximum temperature during sanitization:</strong></td>
<td class="column-2">125 °C (257 °F) x 30 min or 145 °C (293 °F) x 30 min for the “LP” version</td>
</tr>
<tr class="row-8 even">
<td class="column-1"><strong>Response time to variations in temperature:</strong></td>
<td class="column-2">2’/10 °C (18 °F).</td>
</tr>
<tr class="row-9 odd">
<td class="column-1"><strong>Relative Line Pressure:<br />
</strong></td>
<td class="column-2">max. 10 bar (145 psi) at 20 °C (68 °F)<br />
max. 8 bar (116 psi) at 100 °C (212 °F)<br />
Special configuration for pressures till 25 bar (362 psi) at 100 °C (212 °F)</td>
</tr>
</tbody>
</table>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-7206" src="https://www.milktronics.com/wp-content/uploads/2020/06/3-a_logo_certificate.gif" alt="3A logo Refractometer" width="100" height="85" /></p>
<p>For the waste water version please click here : https://www.milktronics.com/product/ur-62-maselli/</p>
<p>The post <a href="https://www.milktronics.com/product/online-refractometer-sugar-brix/">Maselli UR24</a> appeared first on <a href="https://www.milktronics.com">Milktronics Online instruments</a>.</p>
]]></content:encoded>
					
		
		
			</item>