Satron VOA Configuration Codes & Selection Guide 60 Hz outputs J/K; wetted materials 221; cable length 2 (10 m) where required; no cable material 5 or length 3. VOA PRIME uses housings N or L, light-source code 1 (RED & IR), and process connection G1. N uses T (M12); L uses probe 0 and V (PG9). Remote probe R is available with N. Remote probe/electronics use cable material 2 (AISI316L braided PTFE hose) or 4 (PVC), length 2 (10 m). Integral N uses cable codes 00. Cable material 2 is outside 3-A approval. Output K: N housing only. Material code 221 uses AISI316L, sapphire and FEP + EPDM. The manufacturer limits EPDM to process media at or below 8% fat. High-temperature 3-A approval requires FFPM, so the H/221 combinations listed here must not be specified as 3-A-approved high-temperature assemblies. Confirm application suitability with Milktronics before ordering. Source: BA201, M3 revision 1.3, 13 October 2025 VOANJ221N0T001G1 VOANJ221NRT221G1 VOANJ221NRT421G1 VOANJ221L0V221G1 VOANJ221L0V421G1 VOANK221N0T001G1 VOANK221NRT221G1 VOANK221NRT421G1 VOAHJ221N0T001G1 VOAHJ221NRT221G1 VOAHJ221NRT421G1 VOAHJ221L0V221G1 VOAHJ221L0V421G1 VOAHK221N0T001G1 VOAHK221NRT221G1 VOAHK221NRT421G1