Compare 16 Satron VOA configuration codes for the Milktronics selection below. This guide helps identify the requested sensor options and prepare a quotation.
Selection scope
60 Hz outputs J/K; wetted materials 221; cable length 2 (10 m) where required; no cable material 5 or length 3.
VOA PRIME uses housings N or L, light-source code 1 (RED & IR), and process connection G1. N uses T (M12); L uses probe 0 and V (PG9). Remote probe R is available with N. Remote probe/electronics use cable material 2 (AISI316L braided PTFE hose) or 4 (PVC), length 2 (10 m). Integral N uses cable codes 00. Cable material 2 is outside 3-A approval.
Output K is included only with N housing, as required by the manufacturer’s IO-Link footnote. This is a selected range, not the full manufacturer catalog.
How to read a Satron VOA code
Example: VOANJ221N0T001G1. Read the fields in the order shown below.
| Field | Meaning |
|---|---|
| Model | VOA |
| Process temperature | N: −5 to +100 °C; H: −5 to +140 °C |
| Output | J: 4–20 mA/HART, 60 Hz. K: adds IO-Link, N housing only. |
| Wetted materials | 221: AISI316L body, sapphire lens, FEP + EPDM seal. |
| Housing | N: display, two analog outputs and binary I/O; L: remote electronics with display. |
| Probe | 0: no remote probe. R: remote measuring probe with N housing. |
| Electrical connection | T: M12; V: PG9 for L housing. |
| Cable | 00: no remote cable option; 22: braided PTFE hose, 10 m; 42: PVC, 10 m. |
| Light source | 1: RED & IR. |
| Process connection | G1: standard G1A thread + O-ring. |
Application and approval notes
Material code 221 uses AISI316L, sapphire and FEP + EPDM. The manufacturer limits EPDM to process media at or below 8% fat. High-temperature 3-A approval requires FFPM, so the H/221 combinations listed here must not be specified as 3-A-approved high-temperature assemblies. Confirm application suitability with Milktronics before ordering.
Download the configuration list
Download all 16 Satron VOA configuration codes (TXT)
All 16 selected combinations
VOANJ: normal process temperature, output J
VOANJ221N0T001G1VOANJ221NRT221G1VOANJ221NRT421G1VOANJ221L0V221G1VOANJ221L0V421G1
VOANK: normal process temperature, output K
VOANK221N0T001G1VOANK221NRT221G1VOANK221NRT421G1
VOAHJ: high process temperature, output J
VOAHJ221N0T001G1VOAHJ221NRT221G1VOAHJ221NRT421G1VOAHJ221L0V221G1VOAHJ221L0V421G1
VOAHK: high process temperature, output K
VOAHK221N0T001G1VOAHK221NRT221G1VOAHK221NRT421G1
Manufacturer source and product
Based on Satron datasheet BA201, M3 revision 1.3, 13 October 2025. Read the manufacturer selection chart (PDF).
View the Satron VOA product | Browse Satron products | Request configuration assistance