Turbidity Sensors and Meter for Inline Turbidity Measurement HAZE control Online turbidity meter high quality
VOD 0-1500NTU Absorption Local Display

VOD 0-1500NTU Absorption Local Display

Very accurate on low turbidity levels. 0-5NTU applications such as COW, polisher or reverse osmosis. Robust, easy to install, the meter comes plug and play. Many display options.

Product downloads

Category:

Description

Very sensitive meter to detect impurities in water. Perfect for polisher, Reverse osmosis or COW water. Calibration is usually 0-20NTU. When the contamination reaches 5NTU the flow is diverted to waste. HAZE control. Perfectly hygienic, the meter comes the pipe and is already calibrated on Formazin. High temperature option is available for condensate applications.

  • Absorption Range : 0-10-50-1500 FTU-NTU-g/L-%...(any range available)
  • High temperature option available 300°F  150°C 
  • 100°C (212°F)  150°C (300°F) continious with high temperature option
  • LED long life aging auto-compensated
  • 180° light transmission.
  • Power: 24VDC Output : 4-20mA
  • HART protocole
  • seals: EPDM, Viton, Kalrez
  • 1" to 6" pipe diameter available
  • Wavelengths infrared (880nm NIR)
  • auto cleaning available

Turbidity meter with UL 3A EHEDG CE